Start Discovering Solved Questions and Your Course Assignments
TextBooks Included
Active Tutors
Asked Questions
Answered Questions
a millivolt recorder is available with a total range of 0 to 10 mv and an accuracy of plusmn025 percent of full scale
1 a chromel-alumel thermocouple is exposed to a temperature of 1560f the potentiometer is used as the cold junction and
1 for a certain thermistor beta 3420 k and the resistance at 200f is known to be 1010 plusmn 3 omega the thermistor is
a bimetallic strip of yellow brass and monel 400 is bonded at 120f the thickness of the yellow brass is 0014 plusmn
suppose the bimetallic strip in prob 83 is used to indicate temperatures of 150 200 and 300f the tip of the strip is
1 what are the major disadvantages of rtds2 calculate the temperature at which the fahrenheit and celsius scales
a heavily oxidized aluminum plate is exposed to a flow stream having a heat transfer coefficient of 50 wm2c the plate
a thermocouple data logger has a built-in circuit to compensate for the temperature of the connecting board which is
1 a thermometer having an emissivity of 09 is placed in a large room and indicates a temperature of 25cthe walls of the
1 a thermopile is to be constructed for measuring small temperature differences devise arrangements to measure
consider a thin thermocouple that behaves like iron having dimensions of 05 times 01 times 0005 in calculate the time
a bimetallic strip is to be constructed of yellow brass and invar for the purpose of measuring temperature over the
a certain high-speed temperature probe having a recovery factor of 098plusmn001 is used to measure the temperature of
what would be the voltage output of the thermopile in prob 860 if the cooler junction was maintained at 0cprob 860a
a thermopile is constructed of type n thermocouple wire having 10 junction pairs one set of junctions is assembled and
using the results of prob 847 determine the true metal temperature when the pyrometer indicates 450c and the
the radiation from a metal part is measured with a pyrometer which indicates a temperature of 300c the actual part
closed book exam hand in blue books to keck laboratory by 9am ------------------------------------------------ beam is
list the phases that form on cooling a steel alloy 76 wt c continuosly from 750c to rt use cooling rate 170s 1s 20s
if l 9 m the beam will fail when the maximum shear force is vmax 5 kn or the maximum bending moment is mmax 22 kn
repeat prob 874 for a highly polished aluminum surfaceprob 874a plate of aluminum which has become heavily oxidized
alternate thermocouple measurement techniques are proposed for measuring the temperature difference between inlet and
the temperature of a surface is to be measured with a radiometer at temperature levels of 350 and 600 k the emissivity
the strengthening of a polycrystalline metal is provided by grain refinement and dispersion of particles the tensile
a steel with a grain size of 25 mm has a yield stress of 200 mpa and with a grain size of 9 mm a yield stress of 300