Start Discovering Solved Questions and Your Course Assignments
TextBooks Included
Active Tutors
Asked Questions
Answered Questions
a 100-turn coil in the configuration of figure p1213 is rotated at a constant speed of 1200 rmin in a magnetic field
the coil is placed so that its axis of revolution is perpendicular to a uniform field as shown in figure p12110 if the
an elementary two-pole single-phase synchronous machine as illustrated in figure p1221 has a field winding on its rotor
the flux-density distribution in the air gap of a 60-hz two-pole salient-pole machine is sinusoidal having an amplitude
consider an elementary three-phase four-pole alternator with a wye-connected armature winding consisting of full-pitch
a wye-connected three-phase 50-hz six-pole synchronous alternator develops a voltage of 1000 v rms between the lines
determine the synchronous speed in revolutions per minute and the useful torque in new ton meters of a 200-hp 60-hz
from a three-phase 60-hz system through a motor-generator set consisting of two directly coupled synchronous machines
two coupled synchronous machines are used as a motor-generator set to link a 25-hz system to a 60-hz system find the
a 10-turn square coil of side 200 mm is mounted on a cylinder 200 mm in diameter if the cylinder rotates at 1800 rmin
let the coil of the solenoid of problem 1246 have a resistance r and be excited by a voltage v vm sin omegat consider
for the electromagnet shown in figure p1243 the lambda-i relationship for the normal working range is given by i
a four-pole dc series motor has a lap-connected two-layer armature winding with a total of 400 conductors calculate the
a four-pole dc generator is lap wound with 326 armature conductors it runs at 650 rmin on full load with an induced
a four-pole lap-wound armature has 144 slots with two coil sides per slot each coil having two turns if the flux per
a four-pole dc machine with 728 active conductors and 30 m wb flux per pole runs at 1800 rmina if the armature winding
the per-phase equivalent circuit shown in figure 1326 of a three-phase 600-v 60-hz four pole wye-connected wound-rotor
a 500-hp wye-connected wound-rotor induction motor when operated at rated voltage and frequency develops its rated
a three-phase induction motor operating at its rated voltage and frequency develops a starting torque of 16 times the
the power transferred across the air gap of a two pole induction motor is 24 kw if the electromagnetic power developed
a three-phase 5-hp 220-v six-pole 60-hz induction motor runs at a slip of 0025 at full load rotational and stray-load
a balanced three-phase 60-hz voltage is applied to a three-phase two-pole induction motor corresponding to a per-unit
a dc shunt motor runs off a constant 200-v supply the armature winding resistance is 04 omega and the field winding
a 100-kw dc shunt generator connected to a 220-v main is belt-driven at 300 rmin when the belt suddenly breaks and the
a dc shunt machine has an armature winding resistance of 012 omega and a shunt-field winding resistance of 50 omega the