AC Wave Winding

Introduction to AC Wave Winding:

Build up a single phase, single layer wave winding for a 4 pole, 24 slot ac machine.

Solution: Number of coils i.e. C = 12

The pole pitch = Number of slots/Number of Poles

= 24/4= 6; and slots per pole per phase, m = 6/1 = 6

Slots from 1 to 6 and 13 to 18 lie within North Pole regions N1 and N2 correspondingly. Likewise slots from 7 to 12 and 19 to 24 lie within South Pole regions S1 and S2 correspondingly. Other words, the 1st pole pair covers slots 1 to 12 and the 2nd pole pair covers slots from 13 to 24.

For full pitch winding, angle among the two sides of similar coil is 1800ed. 1800ed corresponds to 6 slots.

And for the ac wave winding, back pitch,

Yb = number of coils (or slots) per pole= 6 = front pitch, Yf.

If one side of the coil is located in slot number 1, another side of the coil should be located in slot number (1 + slots per pole = 1 + 6 =) 7. The coil's finishing end side at slot number 7 is connected to the starting end of the coil side at slot number (7 + 6 =) 13. Now another side of the coil side at slot number 13 is located at slot number (13 + 6 =) 19. Adding 6 to slot number 19 provides 25 that is slot number 1, that is, 25 - 24 = 1. But a coil side is already located at slot number 1. So add 1 and place the coil side at slot number 2. Likewise, add turn by turn back pitch and front pitch and at the end of each round add Yb + 1. The below Table provides the complete winding table for a 4 pole 24 slot ac wave wound machine.

Table:  Single Phase AC Wave Winding Table

S.No.

Yf

Y b

1

2

3

4

5

6

7

8

9

10

11

12

1

13

2

14

3

15

4

16

5

17

6

18

7

19

8

20

9

21

10

22

11

23

12

24

To sketch the main winding diagram, solid lines of equivalent length and equal distance equal to number of slots is drawn. Connect the coils according to the Winding Table above.

Arbitrarily suppose a specific current direction to the coil sides within the pole pairs. For the coil sides within North Pole regions, suppose downward current direction and conversely for the South Pole regions, as displayed in the below diagram.

1034_AC Wave Winding Homework Help.jpg

Diagram - Single phase AC Wave Main Winding Diagram

Latest technology based Electrical Engineering Online Tutoring Assistance

Tutors, at the www.tutorsglobe.com, take pledge to provide full satisfaction and assurance in AC Wave Winding homework help via online tutoring. Students are getting 100% satisfaction by online tutors across the globe. Here you can get homework help for AC Wave Winding, project ideas and tutorials. We provide email based AC Wave Winding homework help. You can join us to ask queries 24x7 with live, experienced and qualified online tutors specialized in AC Wave Winding. Through Online Tutoring, you would be able to complete your homework or assignments at your home. Tutors at the TutorsGlobe are committed to provide the best quality online tutoring assistance for Electrical Engineering homework help and assignment help services. They use their experience, as they have solved thousands of the Electrical Engineering assignments, which may help you to solve your complex issues of AC Wave Winding. TutorsGlobe assure for the best quality compliance to your homework. Compromise with quality is not in our dictionary. If we feel that we are not able to provide the homework help as per the deadline or given instruction by the student, we refund the money of the student without any delay.