Question 1:

Three generating units operating in parallel at 60 Hz have rating of 300, 500, and 600    MW and have speed-droop characteristics of 5, 4, and 3%, respectively. Due to a change in load, an increase in system frequency of 0.4 Hz is experienced before any supplementary control action occurs. Determine the amount of the change in system load and also the amount of the change in generation of each unit to absorb the load changes.

Question 2:

A synchronous generator, capable of developing 500MW of power operates at a power angle of 8°. Using equal area criteria, determine by how much the input shaft power can be increased suddenly without loss of stability.

 

   Related Questions in Mechanical Engineering

  • Q : Synchronous generator & Generating units

    Question 1: Three generating units operating in parallel at 60 Hz have rating of 300, 500, and 600    MW and have speed-droop characteristics of 5, 4, and 3%, respectively. Due to a change in load, a

  • Q : Bernoulli's equation From Bernoulli's

    From Bernoulli's equation we know that presure head + velocity head at inlet and outlet header is same. If so  what is ' W' then in the equation ?

  • Q : Poissons Ratio Out of

    Out of Rubber/Steel/Wood, which have higher Poissons Ratio?

  • Q : Problem on discharge head loss Water is

    Water is draining from the tank A to tank B. The elevation difference among the two tanks is 10 m. The pipe joining the two tanks has a sudden-expansion section as shown below. The cross-sectional area of the pipe from A is 8 cm2, and the area of the pipe f

  • Q : Working environment in Product design

    Working environment: The conditions under which the product is likely to be used, stored, and transported must be specified. The product may have to operate in conditions of extreme temperature, be subject to vibration, radiation; these conditions wil

  • Q : Cetane Number and Octane Number

    Describe the term Cetane Number and the Octane Number?

  • Q : Advantages and disadvantages of using

    Explain advantages and disadvantages of using the LPG in Car?

  • Q : Problem on steam turbine 1) A steam

    1) A steam turbine takes in saturated steam at 300oc and outputs steam at 4 bar. When the efficiency of the turbine is 65%, Evaluate: a.  The final composition (vapor vs. liquid) of outgoing steam.b.  The

  • Q : Petroleum technology theories for the

    theories for the origin of petroleum, methods for detection of petroleum deposits, fractional distillation

  • Q : What is cotter joint Explain what is

    Explain what is meant by the Cotter joint?