Synchronous generator & Generating units

Question 1:

Three generating units operating in parallel at 60 Hz have rating of 300, 500, and 600    MW and have speed-droop characteristics of 5, 4, and 3%, respectively. Due to a change in load, an increase in system frequency of 0.4 Hz is experienced before any supplementary control action occurs. Determine the amount of the change in system load and also the amount of the change in generation of each unit to absorb the load changes.

Question 2:

A synchronous generator, capable of developing 500MW of power operates at a power angle of 8°. Using equal area criteria, determine by how much the input shaft power can be increased suddenly without loss of stability.

 

   Related Questions in Mechanical Engineering

  • Q : Difference between pressure vessel &

    Difference between pressure vessel & column: The Pressure vessels (cylinder or tank) are utilized to store fluids under pressure. If the pressure vessel are design in the form of column to separate the gas at u

  • Q : Define Mechanism Mechanism : The

    Mechanism: The mechanism is a system of moving parts which changes an input motion and force into the desired output force and motion.

  • Q : Describe Process Flow Diagram Process

    Process Flow Diagram: A Process Flow Diagram or System Flow Diagram exhibits the relationships among the main components in the system. It too has fundamental information regarding the material balance for the process.

  • Q : Causes and consequences of dynamic

    Discuss the causes and consequences of dynamic loading on structures based on two real examples. Support your discussion with proper diagrams or sketches. Your discussion shall include the time and location of the event, type and source of dynamic loa

  • Q : Product appearance in Product design

    Product appearance: Strongly influenced by the Industrial Designer, the general style? of the product is significant as this will have an influence on materials and manufacturing procedures to be used. The product should be able to grab the customer's

  • Q : Problem on discharge of water In the

    In the below system, d = 6 in., D = 12 in., Δz1 = 6 ft, and Δz2 = 12 ft. The discharge of water in the given system is 10 cfs. Is the machine a turbine or a pump ? Determine the pressures at points A and B? Neglect head losses. Suppos

  • Q : To designe pump how to design e gear

    how to design e gear pump. show the process.

  • Q : Calculating liquid composition There

    There is a 35% MeOH/water mix to feed to a flash at 100 Ib- mole /hr and 1 atm. We want a vapour composition of 60 % MeOH. What does the vapour flow rate need to be? What is the liquid composition? Give the equation of the operation line?

    Q : Problem on steam turbine 1) A steam

    1) A steam turbine takes in saturated steam at 300oc and outputs steam at 4 bar. When the efficiency of the turbine is 65%, Evaluate: a.  The final composition (vapor vs. liquid) of outgoing steam.b.  The

  • Q : Stop cooling-water flow in turbine

    Whether you stop cooling-water flow through steam condenser when the turbine is slopped?