Synchronous generator & Generating units

Question 1:

Three generating units operating in parallel at 60 Hz have rating of 300, 500, and 600    MW and have speed-droop characteristics of 5, 4, and 3%, respectively. Due to a change in load, an increase in system frequency of 0.4 Hz is experienced before any supplementary control action occurs. Determine the amount of the change in system load and also the amount of the change in generation of each unit to absorb the load changes.

Question 2:

A synchronous generator, capable of developing 500MW of power operates at a power angle of 8°. Using equal area criteria, determine by how much the input shaft power can be increased suddenly without loss of stability.

 

   Related Questions in Mechanical Engineering

  • Q : SI Engines Illustrate why several types

    Illustrate why several types of the sound are generated in different bikes, although they run on the SI Engines?

  • Q : Mechanical design for manufacturing A

    A stone quarry in a remote part of the world requires that stone blocks of 3 cubic feet in volume be moved up a 50 ft long ramp which is inclined at 30 degrees. Since the location is remote, the blocks must be moved usng human power. On a continuous basis, human power

  • Q : Solution A pump station has been

    A pump station has been designed to lift water out of a 6 metre deep pit (vented to atmosphere) via a centrifigual pump mounted at ground level. Liquid conditions 20OC Suction pipe work losses 2.0 metres NPSH safety factor 5.0 kPa Vapor pressure @ 20oC 0.25 metres (a) Calculat

  • Q : Problem on discharge of water In the

    In the below system, d = 6 in., D = 12 in., Δz1 = 6 ft, and Δz2 = 12 ft. The discharge of water in the given system is 10 cfs. Is the machine a turbine or a pump ? Determine the pressures at points A and B? Neglect head losses. Suppos

  • Q : Static and Dynamic load What are Static

    What are Static and Dynamic load and what are their significant dynamic effects?

  • Q : Formulating equation of motion Figure

    Figure below shows a reinforced concrete framed building subjected to earthquake ground motion. The floor is rigid with the mass of each floor is shown in the figure. Formulate the equation of motion for this building. Prove that the natural frequenci

  • Q : Describe Process Flow Diagram Process

    Process Flow Diagram: A Process Flow Diagram or System Flow Diagram exhibits the relationships among the main components in the system. It too has fundamental information regarding the material balance for the process.

  • Q : Quantity in Product design specification

    Quantity: The total quantity of the product predicted and, more importantly, the production rates and batch sizes needed, should be specified. This will have implications for the types of manufacturing equipment and work organization necessary. It wil

  • Q : Explain steam turbine diaphragm Steam

    Steam turbine diaphragm: Steam turbine includes of phases, number and size of the phases depends on the break horse-power of the turbine. The phase has set of moving and fixed blades. Moving blades are joined to th

  • Q : Synchronous generator & Generating units

    Question 1: Three generating units operating in parallel at 60 Hz have rating of 300, 500, and 600    MW and have speed-droop characteristics of 5, 4, and 3%, respectively. Due to a change in load, a