Problem on heat required for process

A steady-state flow process is used to heat methanol in a tank. The incoming stream is at 2 bar and 25 oC and has a flow rate of 5 kg/s. The outgoing stream is at 1 bar, 100 oC. Heating is provided by a heating coil immersed in a tank. Given the following data, calculate the amount of heat required for this process.

Methanol at 2 bar:

Boiling point is 83 oC
Heat capacity, vapor, is 60 J/mol/K
Heat capacity, liquid, is 80 J/mol/K
Heat of vaporization is 36740 J/mol

   Related Questions in Chemical Engineering

  • Q : How to balance Chemical Reaction

    Consider a chemical reaction: a CH3-CH=CH2 + b NH3 + c O2 → d CH2=CH-C≡N + e H2O 1.  &

  • Q : Calculate the pressure Calculate the

    Calculate the pressure at the bottom of a column of Ethanol 100 ft high using a pressure (force) balance in American Engineering Units.

  • Q : I need to solve the material and energy

    I need to solve the material and energy balance for the att.

  • Q : Chemical flow I) Sulphur dioxide (SO2)

    I) Sulphur dioxide (SO2) with a volumetric flow rate 5000cm3/s at 1 bar and 1000C is mixed with a second SO2 stream flowing at 2500cm3/s at 2 bar and 200C. The process occurs at steady state. You may assume ideal gas behaviour. For SO2 take the heat capacity at constant pressure to be CP/R = 3.267+5

  • Q : Hh to determine the temperature that

    to determine the temperature that occurred in a fire in a warehouse, the arson investigator noticed that the relief valve on a methane storage tank had popped open at 3000 psig, the rated value. Before the fire started, the tank was presumably at ambient conditions and the gage read 1950 psig. If th

  • Q : Problem on weight fraction A gas

    A gas contains 350 ppm of H2S in CO2 at 72°F and 1.53 atm pressure. If the gas is liquified, what is the weight fraction H2S?

  • Q : Temprature To determine the temperature

    To determine the temperature that occurred in a ?re in a warehouse, the arson investigator noticed that the relief valve on a methane storage tank had popped open at 3000 psig, the rated value. Before the ?re started, the tank was presumably at ambient conditions and the gage read 1950 psig. If

  • Q : Calculating flow rate of nitrogen The

    The feed of an ammonia synthesis reactor is 25% (lbmole) nitrogen with the balance hydrogen. The flow rate is 3000 kg/h at 65°C and 95 bar. Calculate the flow rate of nitrogen to the reactor in kg/hr.

  • Q : Problem on entropy A heater (heat

    A heater (heat source temperature = 527 K) and turbine are connected in series as shown below:

    Q : Problem on heat required for process A

    A steady-state flow process is used to heat methanol in a tank. The incoming stream is at 2 bar and 25 oC and has a flow rate of 5 kg/s. The outgoing stream is at 1 bar, 100 oC. Heating is provided by a heating coil immersed in a tank. Given the